Babel Buster BB2-7010-01
(formerly IP/XM) contains three different clients and three different servers. The 7010
includes BACnet/IP client and server, Modbus TCP client and server
(master and slave), and Modbus RTU master and slave.
The
BACnet IP client allows BACnet IP devices to be accessible from Modbus
TCP or RTU. You configure the device instance, object type and
instance, and poll interval for reading or writing BACnet objects. The
object data is stored in the IP/XM server for subsequent retrieval by
any supported remote client (or master).
A
large number of BACnet objects gives you flexibility in mapping Modbus
registers to any combination of BACnet objects. Packed Modbus registers
may be parsed to multiple BACnet objects when reading. Multiple BACnet
objects may be packed into a single Modbus register when writing. All
standard Modbus register types are supported.
Value
objects will poll their assigned Modbus register at the interval you
specify. The content of the Modbus register will be given as the
Present Value of the BACnet object when read. The Modbus register is
written each time the BACnet Value object is written. The Value object
corresponds well with the Modbus Holding register.
Input
objects will poll their assigned Modbus register at the interval you
specify, and provide the Modbus data as the Present Value when read.
Commandable Output objects are used to write Modbus registers, and will
update the Modbus device each time BACnet is updated.
The same polling schemes that apply to Modbus also apply to remote BACnet IP slaves polled by the 7010's BACnet IP client.
• Universal, fully configurable
• No extra software or drivers to buy
• Read/Write any standard Modbus register via BACnet
• Read/Write any standard BACnet object via Modbus
• Bidirectional communication between BACnet and Modbus
• Supports Modbus “coils”, input registers, holding registers
• Single or double Modbus registers
• Signed, unsigned, IEEE 754
• Modbus register mapping configured via web interface
• Modbus registers may be scaled (x10, x0.1, etc.)
• Modbus (master) polling interval configurable per point
• Commandable BACnet objects implement priority array
• Hardened EIA-485 transceiver for Modbus RTU
• 10/100BaseT Ethernet for BACnet IP and Modbus TCP
• Powered by 10-30VDC or 12-24VAC 50/60 Hz
• Power Consumption: 0.1A @ 24VDC
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Pluggable screw terminal block for power & RTU network
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class A, CE Mark |