The goal of i.CanDoIt® is to provide a simple and cost effective facility management and remote monitoring solution suitable for use in small sites. i.CanDoIt®
includes data logging, time & date scheduling, and template or rule
based alarm processing with email notification and/or I/O activation in
response to events. Data logging simply records the contents of
registers on a user specified schedule. Event logging keeps a record of
alarm events. Scheduling causes register values to be set according to
a schedule. The resulting register manipulation may generate network
communication with remote devices, control local I/O, or change
setpoints. The i.CanDoIt® is programmable, even though it is rather powerful without programming.
The BACnet version of the i.CanDoIt®
server features a BACnet IP client and server. This server is ideal
I/O add-on or stand alone controller for a BACnet IP system. The i.CanDoIt® BACnet controller is freely programmable.
Control Solutions’ AddMe III features 18 universal inputs which are context sensitive. When configured as an analog input, the continuously self-calibrating
sigma-delta converter produces 15-bit resolution with high noise
immunity. When configured as a discrete input, the converter switches
to 8-bit resolution at 128 samples per second for fast response.
Analog
data is available via Analog Input objects. Linearization tables are
provided for 10K and 20K type II, III, and IV thermistors on analog
inputs. Input and output type and scaling are configured in web pages
served by the internal web server. Outputs are accessed via commandable
Analog Output and Binary Output objects. Additional uncommitted
writeable Analog Input objects, plus writeable Multistate Input
objects, are available for the user program.
The
AddMe III BACnet IP server includes a Modbus RTU gateway for
interfacing multiple Modbus devices to BACnet IP. Devices one may
interface include VFD's, power monitors, etc.
• 18 Analog/universal inputs
• 0-10VDC, Thermistor, dry contact
• Software selectable input type
• 0.1% reference, up to 16-bit resolution
• Continuously self-calibrating sigma-delta converter
• 4 Analog outputs
• 4-20mA (0-20mA)
• 8-bit resolution
• 8 Discrete outputs
• Form A relay, 5A @ 120VAC
• HOA switches & LED status indicators
• 2 Pulse/Discrete inputs
• TTL to 24VDC
• Rate or totalizing count input
• 10/100BaseT Ethernet, BACnet IP
• Modbus RTU RS-485 Master gateway
• Data and event logger, email & trap notifications
• Real time scheduler including astronomical clock
• Web interface including user HTML wrapper
• User programmable using PL/i
• Powered by 18-30VDC or 24VAC 50/60 Hz
• Power Consumption: 0.3A @ 24VDC max.
• DIN rail mounting, 100mm H x 155mm W x 60mm D
• LED indicators for power, status, Tx/Rx, comm error
• Pluggable screw terminal blocks
• Operating temperature -40°C to +70°C
• Humidity 5% to 90%
• FCC Class A, CE Mark |