The goal of i.CanDoIt® is to provide a simple and cost effective facility management and remote monitoring solution suitable for use in small sites. i.CanDoIt®
includes data logging, time & date scheduling, and template or rule
based alarm processing with email notification and/or I/O activation in
response to events. Data logging simply records the contents of
registers on a user specified schedule. Event logging keeps a record of
alarm events. Scheduling causes register values to be set according to
a schedule. The resulting register manipulation may generate network
communication with remote devices, control local I/O, or change
setpoints. The i.CanDoIt® is programmable, even though it is rather powerful without programming.
The BACnet version of the i.CanDoIt®
server features a BACnet IP client and server. This server is ideal
I/O add-on or stand alone controller for a BACnet IP system. The i.CanDoIt® BACnet controller is freely programmable.
Control Solutions’ i.CanDoIt® AddMe Jr.
features 12 inputs which accept analog input from thermistors or 0-10V
sensors, or discrete input from dry contact switches. Model AMJR-14
also provides 2 discrete outputs which can sink 1A at 24VDC.
Analog
data is available via Analog Input objects. Linearization tables are
provided for 10K and 20K type II, III, and IV thermistors on analog
inputs. Input and output type and scaling are configured in web pages
served by the internal web server. Outputs are accessed via commandable
Binary Output objects. Additional uncommitted writeable Analog Input
objects, plus writeable Multistate Input objects, are available for the
user program.
The
AddMe III BACnet IP server includes a Modbus RTU gateway for
interfacing multiple Modbus devices to BACnet IP. Devices one may
interface include VFD's, power monitors, etc.
• 12 Analog/universal inputs
• 0-10VDC, Thermistor, dry contact
• Software selectable input type
• 10-bit resolution
• 2 channels capable of pulse count input
• 2 Discrete outputs
• Open drain FET, 1A current sink
• 10/100BaseT Ethernet, BACnet IP
• Modbus RTU RS-485 Master gateway
• Data and event logger, email & trap notifications
• Real time scheduler including astronomical clock
• Web interface including user HTML wrapper
• User programmable via PL/i
• Powered by 18-30VDC or 24VAC 50/60 Hz
• Power Consumption: 0.3A @ 24VDC max.
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Pluggable screw terminal blocks
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class B, CE Mark |