Babel Buster BB2-7010-02
(formerly IP/XM-SNMP) contains four different clients and four different servers. The
IP/XM-SNMP includes BACnet/IP client and server, Modbus TCP client and
server (master and slave), SNMP client and server (agent), and Modbus
RTU master and slave.
The
BACnet IP client allows BACnet IP devices to be accessible from Modbus
or SNMP. You configure the device instance, object type and instance,
and poll interval for reading or writing BACnet objects. The object
data is stored in the 7010 server for subsequent retrieval by any
supported remote client.
The
SNMP client allows SNMP devices to be accessible from BACnet
IP or Modbus. You configure the SNMP agent's IP address, the OID of the
MIB variable you wish to poll, and set a polling interval. The object
data is stored in the 7010 server for subsequent retrieval by any
supported remote client.
A
large number of BACnet objects gives you flexibility in mapping Modbus
registers to any combination of BACnet objects. Packed Modbus registers
may be parsed to multiple BACnet objects when reading. Multiple BACnet
objects may be packed into a single Modbus register when writing. All
standard Modbus register types are supported.
Value
objects will poll their assigned Modbus register at the interval you
specify. The content of the Modbus register will be given as the
Present Value of the BACnet object when read. The Modbus register is
written each time the BACnet Value object is written. The Value object
corresponds well with the Modbus Holding register.
Input
objects will poll their assigned Modbus register at the interval you
specify, and provide the Modbus data as the Present Value when read.
Commandable Output objects are used to write Modbus registers, and will
update the Modbus device each time BACnet is updated.
The
same polling schemes that apply to Modbus also apply to remote BACnet
IP slaves polled by the 7010's BACnet IP client, and to remote
SNMP agents polled by the 7010's SNMP client.
• Universal, fully configurable
• No extra software or drivers to buy
• Read/Write any standard Modbus register
• Read/Write any standard BACnet object
• Read/Write common SNMP MIB variables
• Includes BACnet client and server
• Includes Modbus TCP client and server (master, slave)
• Includes Modbus RTU master and slave
• Includes SNMP client and server (agent)
• Bidirectional communication between protocols
• Supports Modbus “coils”, input registers, holding registers
• Single or double Modbus registers
• Signed, unsigned, IEEE 754
• Modbus register mapping configured via web interface
• Modbus registers may be scaled (x10, x0.1, etc.)
• Modbus (master) polling interval configurable per point
• Commandable BACnet objects implement priority array
• Hardened EIA-485 transceiver for Modbus RTU
• 10/100BaseT Ethernet for BACnet IP, Modbus TCP, SNMP
• Powered by 10-30VDC or 12-24VAC 50/60 Hz
• Power Consumption: 0.1A @ 24VDC
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Pluggable screw terminal block for power & RTU network
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class A, CE Mark |