Control Solutions Babel Busterฎ BB2-3010 is
a BACnet MS/TP client/server device that functions as a Modbus RTU
master/slave. A large number of BACnet objects gives you flexibility in
mapping Modbus registers to any combination of BACnet objects. Packed
Modbus registers may be parsed to multiple BACnet objects when reading.
Multiple BACnet objects may be packed into a single Modbus register
when writing. All standard Modbus register types are supported.
Input
objects will poll their assigned Modbus register at the interval you
specify, and provide the Modbus data as the Present Value when read.
Commandable Output objects are used to write Modbus registers, and will
update the Modbus device each time BACnet is updated. The BB2-3010
supports up to 300 non-commandable objects, or up to 135 commandable
objects, or a mix in between.
Value
objects will poll their assigned Modbus register at the interval you
specify. The content of the Modbus register will be given as the
Present Value of the BACnet object when read. The Modbus register is
written each time the BACnet Value object is written. The Value object
corresponds to the Modbus Holding register.
The
BB2-3010 is most often used as a Modbus master, but it can operate as a
slave while MS/TP operates as a client (master). This makes it possible
to put MS/TP devices on a Modbus network (but does still require an
understanding of BACnet). MS/TP data in remote devices is queried and
saved locally. The local data may then be accessed by another Modbus
master.
Universal, fully configurable
No extra software or drivers to buy
Free configuration software
Read/Write Modbus registers via BACnet objects
300 Non-commandable objects OR
135 Commandable objects OR
Between 135 and 300 objects of mixed types.
Object allocations are user configurable
AI, AO, AV, BI, BO, BV, MSI, MSO, MSV objects
COV, COVP subscription support
BACnet slave is Modbus RTU master or vice versa
Bidirectional communication between BACnet and Modbus
Supports Modbus coils, input registers, holding registers
Single or double Modbus registers
Signed, unsigned, IEEE 754, single bit
Modbus register mapping configured via object properties
Modbus registers may be scaled
Modbus (master) polling interval configurable per point
Commandable BACnet objects implement priority array
Hardened EIA-485 transceiver for serial ports
MS/TP baud rates: 9600, 19200, 38400, 76800
Modbus RTU baud rates: 4800, 9600, 19200, 38400
Powered by 10-30VDC or 12-24VAC 50/60 Hz
Power Consumption: 0.1A @ 24VDC
DIN rail mounting, 100mm H x 70mm W x 60mm D
Pluggable screw terminal blocks
Operating temperature -40ฐC to +85ฐC
Humidity 5% to 90%
FCC, CE Mark
Fully configurable via BACnet object properties
USB to MS/TP adapter available
Configuration software included for use with USB adapter
Note: You will need an MTX002 USB to MS/TP adapter to configure the BB2-3010.
|